<?xml version="1.0" encoding="UTF-8"?><rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>UPS Card Guide: SNMP Network Cards and NUT Support</title><description>Plain guides to SNMP network management cards for UPS units and NUT support, built from published official documentation.</description><link>https://upscardguide.com/</link><language>en</language><atom:link href="https://upscardguide.com/rss.xml" rel="self" type="application/rss+xml"/><item><title>UPS Card Compatibility for SmartSlot, Mini-Slot, and X-Slot</title><link>https://upscardguide.com/posts/ups-card-slot-compatibility-smartslot-mini-slot-x/</link><guid isPermaLink="true">https://upscardguide.com/posts/ups-card-slot-compatibility-smartslot-mini-slot-x/</guid><description>Match APC SmartSlot, Eaton Mini-Slot, and Eaton X-Slot network cards to your UPS model. Check card part numbers, firmware, and bracket requirements.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;For an APC SmartSlot, look up the UPS model in Schneider Electric’s card chart. For Eaton, start with NETWORK-M3 for a supported Mini-Slot UPS or INDGW-X2 for a supported X-Slot UPS. Buy only after the manufacturer’s compatibility list confirms the card for your UPS model and slot. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC compatibility chart&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na.html&quot;&gt;Eaton Mini-Slot specifications&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/cr/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-industrial-gateway-card.html&quot;&gt;Eaton X-Slot specifications&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;UPS network card compatibility matrix&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Slot&lt;/th&gt;
&lt;th&gt;Card model&lt;/th&gt;
&lt;th&gt;Example UPS matches&lt;/th&gt;
&lt;th&gt;What to check&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;APC SmartSlot&lt;/td&gt;
&lt;td&gt;AP9640, AP9641, AP9643 (NMC3)&lt;/td&gt;
&lt;td&gt;Smart-UPS model prefixes include SMT, SMX, and SRT.&lt;/td&gt;
&lt;td&gt;For SUA, check for a manufacture date after 2008 and firmware v1.4.2 or later. For Symmetra PX 250/500, the chart specifies AP9643 only. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC chart&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;APC SmartSlot&lt;/td&gt;
&lt;td&gt;AP9544 (NMC3)&lt;/td&gt;
&lt;td&gt;Listed single-phase Easy UPS On-Line models include the SRV1KA.&lt;/td&gt;
&lt;td&gt;The SRV1KA requires the alternate bracket supplied with the card. Check the chart for the other models that require it. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC chart&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Eaton Mini-Slot&lt;/td&gt;
&lt;td&gt;NETWORK-M3&lt;/td&gt;
&lt;td&gt;5P, 5PX, 5PX G2, 5SC Rack, and 9PX are among the listed models.&lt;/td&gt;
&lt;td&gt;For 93PS, Eaton specifies firmware 2.50 or later. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na.html&quot;&gt;NETWORK-M3 specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Eaton X-Slot&lt;/td&gt;
&lt;td&gt;INDGW-X2&lt;/td&gt;
&lt;td&gt;BladeUPS, 9155, 9355, and 9395 are among the listed models.&lt;/td&gt;
&lt;td&gt;Look under &lt;strong&gt;Hardware compatibility&lt;/strong&gt; for your UPS and &lt;strong&gt;UPS slot type&lt;/strong&gt; for X-Slot. &lt;a href=&quot;https://www.eaton.com/cr/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-industrial-gateway-card.html&quot;&gt;INDGW-X2 specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Verify your UPS before ordering&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Copy the full UPS model and check its expansion slot.&lt;/strong&gt; Schneider Electric lists both SmartSlot and a SmartConnect Ethernet port on the SMT1500RM2UC. Use SmartSlot for the card lookup. &lt;a href=&quot;https://www.se.com/us/en/product/SMT1500RM2UC/&quot;&gt;SMT1500RM2UC specifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Match the UPS to the card’s exact model number.&lt;/strong&gt; For SMT1500RM2UC, match the SMT prefix in Schneider Electric’s AP9640, AP9641, and AP9643 row. For an Eaton 9355, find 9355 under &lt;strong&gt;Hardware compatibility&lt;/strong&gt; on the INDGW-X2 page. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC chart&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/cr/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-industrial-gateway-card.html&quot;&gt;INDGW-X2 specifications&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check any firmware or bracket conditions, then check what ships with your UPS.&lt;/strong&gt; Read the notes on the matched row before ordering. Eaton’s 9PX3000RTN specifications list a Mini-Slot and an included NETWORK-M3. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC chart&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na.html&quot;&gt;NETWORK-M3 specifications&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/skuPage.9PX3000RTN.html&quot;&gt;9PX3000RTN specifications&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Look up older Eaton card names&lt;/h2&gt;
&lt;p&gt;Eaton identifies NETWORK-M3 as the upgrade from NETWORK-M2. If you are replacing an M2, confirm the UPS model on the M3 hardware compatibility list. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na.html&quot;&gt;Eaton Gigabit Network Card specifications&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For a discontinued ConnectUPS-X Web/SNMP card, Eaton’s legacy lookup lists the Power Xpert Gateway X-Slot UPS card as the replacement. Confirm the UPS model against the specifications for the card you plan to buy. &lt;a href=&quot;https://www.eaton.com/lt/lt-lt/products/backup-power-ups-surge-it-power-distribution/backup-power-ups/pq-legacy-product.html&quot;&gt;Eaton legacy product lookup&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Schneider Electric’s NMC compatibility chart and Eaton’s NETWORK-M3 and INDGW-X2 specifications were checked on November 26, 2026. Verification was limited to manufacturer documentation.&lt;/p&gt;
</content:encoded><category>ups</category><category>smartslot</category><category>mini-slot</category><category>x-slot</category><category>network-cards</category><author>UPS Card Guide Editorial</author></item><item><title>APC AP9641 vs Eaton Network-M3 vs Tripp Lite WEBCARDLX</title><link>https://upscardguide.com/posts/apc-ap9641-vs-eaton-network-m3-vs-tripp/</link><guid isPermaLink="true">https://upscardguide.com/posts/apc-ap9641-vs-eaton-network-m3-vs-tripp/</guid><description>Compare APC AP9641, Eaton Network-M3 and Tripp Lite WEBCARDLX by UPS compatibility, Ethernet, SNMPv3 and firmware update access.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Match the card to your UPS model first. APC AP9641 fits listed APC Smart-UPS models and needs a Secure NMC subscription for Smart-UPS card firmware 3.0 and later. Eaton Network-M3 fits supported Eaton systems and gets free card firmware updates. Tripp Lite WEBCARDLX is a retired card found in some earlier SmartPro installations. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC compatibility chart&lt;/a&gt; · &lt;a href=&quot;https://www.se.com/us/en/faqs/FA156047/&quot;&gt;Schneider Electric firmware FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na/gigabit-network-card-faq.html&quot;&gt;Eaton Network-M3 FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/tripp-lite-by-eaton-smartonline-ups/smartonline-ups-frequently-asked-questions-faq.html&quot;&gt;Eaton SmartOnline FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/skuPage.SMART1000RM2UN.html&quot;&gt;Tripp Lite SmartPro example&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Match the card to your UPS model&lt;/h2&gt;
&lt;p&gt;Read the full model number of the UPS and the part number of any installed card. Use both when matching the equipment to a vendor listing.&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;UPS you have&lt;/th&gt;
&lt;th&gt;Card to look for&lt;/th&gt;
&lt;th&gt;What to check&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;APC Smart-UPS with an SMT, SMX or SRT model prefix&lt;/td&gt;
&lt;td&gt;AP9641&lt;/td&gt;
&lt;td&gt;Find the UPS prefix under the AP9640, AP9641 and AP9643 entry. &lt;a href=&quot;https://www.se.com/us/en/faqs/FA237786/&quot;&gt;APC compatibility chart&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Eaton 5PX G2&lt;/td&gt;
&lt;td&gt;Network-M3&lt;/td&gt;
&lt;td&gt;Look under the network card question in the 5PX G2 FAQ. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-5px-g2/5px-g2-frequently-aske-questions.html&quot;&gt;Eaton 5PX G2 FAQ&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Tripp Lite SmartPro SMART1000RM2UN&lt;/td&gt;
&lt;td&gt;WEBCARDLX&lt;/td&gt;
&lt;td&gt;Eaton lists WEBCARDLX in the package contents. Match the card label to that part number before looking up firmware. &lt;a href=&quot;https://www.eaton.com/us/en-us/skuPage.SMART1000RM2UN.html&quot;&gt;SMART1000RM2UN product page&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;For the SmartOnline systems in Eaton’s FAQ, the card it names is WEBCARDLXE. Check the exact UPS model before ordering. In Eaton’s firmware catalog, Tripp Lite WEBCARDLXE, Tripp Lite WEBCARD-M3 and Eaton Network-M3 have separate entries. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/tripp-lite-by-eaton-smartonline-ups/smartonline-ups-frequently-asked-questions-faq.html&quot;&gt;SmartOnline FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/products/backup-power-ups-surge-it-power-distribution/firmware-downloads.html&quot;&gt;Eaton firmware catalog&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Ethernet and security&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Card&lt;/th&gt;
&lt;th&gt;Ethernet&lt;/th&gt;
&lt;th&gt;Management and security&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;APC AP9641&lt;/td&gt;
&lt;td&gt;10/100/1000BASE-T&lt;/td&gt;
&lt;td&gt;Environmental monitoring, HTTPS web access and configurable SNMPv3 authentication and privacy. &lt;a href=&quot;https://www.se.com/us/en/product/AP9641/network-management-card-3-nmc3-with-environmental-monitoring-secure-remote-ups-monitoring-and-management/&quot;&gt;AP9641 product page&lt;/a&gt; · &lt;a href=&quot;https://www.se.com/us/en/faqs/FAQ000256000/&quot;&gt;Schneider Electric NMC3 connection FAQ&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Eaton Network-M3&lt;/td&gt;
&lt;td&gt;10/100/1000BASE-T&lt;/td&gt;
&lt;td&gt;HTTPS, SNMPv3, secure boot and a configurable firewall. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na/gigabit-network-card-faq.html&quot;&gt;Eaton Network-M3 FAQ&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Tripp Lite WEBCARDLX&lt;/td&gt;
&lt;td&gt;10/100 Mbps in Eaton’s PDU15NETLX specification&lt;/td&gt;
&lt;td&gt;Eaton lists PowerAlert Device Manager (PADM) and SNMPv3 for the PDU15NETLX with its preinstalled WEBCARDLX. &lt;a href=&quot;https://www.eaton.com/us/en-us/skuPage.PDU15NETLX.html&quot;&gt;Eaton PDU15NETLX specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Firmware updates and licensing&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;APC AP9641 on Smart-UPS.&lt;/strong&gt; Schneider Electric lists an included one-year Secure NMC subscription for the AP9641. For firmware 3.0 or later, add the card to the Secure NMC System Tool, then choose &lt;strong&gt;License Devices&lt;/strong&gt; and &lt;strong&gt;Check License&lt;/strong&gt;. The tool retrieves the included or previously activated subscription. If a license is needed, choose &lt;strong&gt;Continue&lt;/strong&gt; and enter the activation ID from the purchased subscription. Check PowerChute Network Shutdown licensing separately if you use that software. &lt;a href=&quot;https://www.se.com/us/en/product/AP9641/network-management-card-3-nmc3-with-environmental-monitoring-secure-remote-ups-monitoring-and-management/&quot;&gt;AP9641 product page&lt;/a&gt; · &lt;a href=&quot;https://www.se.com/us/en/faqs/FA156047/&quot;&gt;Schneider Electric firmware FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.se.com/us/en/faqs/FAQ000271164/&quot;&gt;PowerChute and card licensing FAQ&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Eaton Network-M3.&lt;/strong&gt; Eaton says card firmware updates are free. In its firmware catalog, open the entry for &lt;strong&gt;Eaton Gigabit Network Card (Network-M3)&lt;/strong&gt; for the firmware, release notes and upgrade instructions. &lt;a href=&quot;https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-gigabit-network-card---na/gigabit-network-card-faq.html&quot;&gt;Eaton Network-M3 FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.eaton.com/us/en-us/products/backup-power-ups-surge-it-power-distribution/firmware-downloads.html&quot;&gt;Eaton firmware catalog&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Tripp Lite WEBCARDLX.&lt;/strong&gt; Start with the product page for the UPS you have. For example, the SMART1000RM2UN page lists &lt;strong&gt;PowerAlert Device Manager (PADM) 20.0.0&lt;/strong&gt; and &lt;strong&gt;LX Firmware Update Instructions (English)&lt;/strong&gt; under &lt;strong&gt;Manuals and user guides&lt;/strong&gt;. Use that model’s listed LX instructions to check the update path for your installed version. &lt;a href=&quot;https://www.eaton.com/us/en-us/skuPage.SMART1000RM2UN.html&quot;&gt;SMART1000RM2UN downloads&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits.&lt;/em&gt; The comparison uses Schneider Electric’s Smart-UPS NMC3 guidance for firmware 3.0 and later, Eaton’s Network-M3 FAQ, and Eaton’s Tripp Lite specifications and PADM 20.0.0 download listing. Documentation was checked on November 26, 2026. The procedures were not run.&lt;/p&gt;
</content:encoded><category>ups</category><category>network cards</category><category>snmp</category><category>firmware</category><author>UPS Card Guide Editorial</author></item><item><title>UPS Network Management Card: No Firmware Subscription?</title><link>https://upscardguide.com/posts/best-ups-network-management-cards-no-firmware-subscription/</link><guid isPermaLink="true">https://upscardguide.com/posts/best-ups-network-management-cards-no-firmware-subscription/</guid><description>Find the Vertiv RDU101 firmware and release notes, check compatibility with your Liebert GXT5 UPS, and identify the software for network shutdown.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Whether the &lt;strong&gt;Vertiv Liebert IntelliSlot RDU101&lt;/strong&gt; requires a firmware subscription remains unconfirmed. Vertiv&apos;s public firmware page lists the card&apos;s firmware and release notes. The RDU101 supports browser access and SNMPv3, and Vertiv lists the &lt;strong&gt;Liebert GXT5 UPS&lt;/strong&gt; as compatible. &lt;a href=&quot;https://www.vertiv.com/en-us/products-catalog/monitoring-control-and-management/monitoring/liebert-intellislot-rdu101-communications-card/&quot;&gt;Vertiv RDU101 product page&lt;/a&gt; · &lt;a href=&quot;https://www.vertiv.com/en-us/support/software-download/monitoring/liebert-intellislot-communications-interface-cards/&quot;&gt;Vertiv card firmware downloads&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Card with public firmware downloads&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Card&lt;/th&gt;
&lt;th&gt;Who it suits&lt;/th&gt;
&lt;th&gt;Where to get card firmware&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Vertiv Liebert IntelliSlot RDU101&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Owners of a Liebert GXT5 UPS who want web access and SNMPv3. &lt;a href=&quot;https://www.vertiv.com/en-us/products-catalog/monitoring-control-and-management/monitoring/liebert-intellislot-rdu101-communications-card/&quot;&gt;Vertiv RDU101 product page&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;Find &lt;strong&gt;RDU101&lt;/strong&gt; in the latest releases table. The row lists the firmware download and release notes. &lt;a href=&quot;https://www.vertiv.com/en-us/support/software-download/monitoring/liebert-intellislot-communications-interface-cards/&quot;&gt;Vertiv card firmware downloads&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Checks before ordering&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Check whether the RDU101 supports your UPS family.&lt;/strong&gt; In the RDU101 product page&apos;s FAQ, look for the question about supported Vertiv products. The answer lists &lt;strong&gt;GXT5 UPS&lt;/strong&gt;. &lt;a href=&quot;https://www.vertiv.com/en-us/products-catalog/monitoring-control-and-management/monitoring/liebert-intellislot-rdu101-communications-card/&quot;&gt;Vertiv RDU101 product page&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Follow the firmware link in the RDU101 row.&lt;/strong&gt; &lt;a href=&quot;https://www.vertiv.com/en-us/support/software-download/monitoring/liebert-intellislot-communications-interface-cards/&quot;&gt;Vertiv card firmware downloads&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check which software supports network shutdown with the RDU101.&lt;/strong&gt; Vertiv lists Power Insight for graceful shutdown over the network on its UPS systems equipped with the RDU101. &lt;a href=&quot;https://www.vertiv.com/en-us/support/faqs/uninterruptable-power-supply-ups/&quot;&gt;Vertiv UPS FAQ&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; Vertiv&apos;s card specifications, UPS FAQ, and RDU101 firmware listing for 1.9.4.0_00001 were checked on November 26, 2026. This guide is not based on hands-on testing. &lt;a href=&quot;https://www.vertiv.com/en-us/support/software-download/monitoring/liebert-intellislot-communications-interface-cards/&quot;&gt;Vertiv card firmware downloads&lt;/a&gt;&lt;/p&gt;
</content:encoded><category>ups</category><category>network-management</category><category>firmware</category><category>snmp</category><author>UPS Card Guide Editorial</author></item><item><title>Poll APC and Eaton UPS Cards: SNMPv3, NUT and Prometheus</title><link>https://upscardguide.com/posts/poll-apc-eaton-ups-cards-snmpv3-nut-prometheus/</link><guid isPermaLink="true">https://upscardguide.com/posts/poll-apc-eaton-ups-cards-snmpv3-nut-prometheus/</guid><description>Poll APC PowerNet and Eaton Network-M2 UPS cards over SNMPv3 with NUT. Verify both with upsc and scrape each UPS separately in Prometheus.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Use the NUT &lt;code&gt;snmp-ups&lt;/code&gt; driver to poll an APC PowerNet UPS card and an Eaton Network-M2 card with SNMPv3 &lt;code&gt;authPriv&lt;/code&gt;. Then give Prometheus one &lt;code&gt;/ups_metrics&lt;/code&gt; scrape job per UPS through &lt;code&gt;nut_exporter&lt;/code&gt;. Start by checking each card&apos;s status in NUT. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter setup&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check SNMPv3 access on each card&lt;/h2&gt;
&lt;p&gt;This setup uses one host for NUT, the exporter and Prometheus. Have NUT with &lt;code&gt;snmp-ups&lt;/code&gt; and Prometheus installed. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter setup&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Start with SNMPv3 enabled and a polling user configured on each card. Have each card&apos;s address, SNMPv3 username, authentication protocol and passphrase, and privacy protocol and passphrase. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Add both UPSes to NUT&lt;/h2&gt;
&lt;p&gt;In &lt;code&gt;ups.conf&lt;/code&gt;, use &lt;code&gt;mibs = apcc&lt;/code&gt; for the APC PowerNet mapping and &lt;code&gt;mibs = eaton_pw_nm2&lt;/code&gt; for Network-M2. Replace the example addresses, usernames and passphrase placeholders. The protocol values are examples. Match them to each card and run &lt;code&gt;snmp-ups -h&lt;/code&gt; to check which algorithms your Net-SNMP build supports. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Keep &lt;code&gt;ups.conf&lt;/code&gt; readable by the NUT processes that need it and restrict access to the file before adding passphrases. &lt;a href=&quot;https://networkupstools.org/docs/user-manual.chunked/NUT_Security.html&quot;&gt;NUT configuration security&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-ini&quot;&gt;[apc-ups]
    driver = snmp-ups
    port = apc-ups.example.com
    mibs = apcc
    snmp_version = v3
    secLevel = authPriv
    secName = REPLACE_APC_USER
    authProtocol = SHA
    authPassword = &amp;quot;REPLACE_APC_AUTH_PASSPHRASE&amp;quot;
    privProtocol = AES
    privPassword = &amp;quot;REPLACE_APC_PRIVACY_PASSPHRASE&amp;quot;

[eaton-ups]
    driver = snmp-ups
    port = eaton-ups.example.com
    mibs = eaton_pw_nm2
    snmp_version = v3
    secLevel = authPriv
    secName = REPLACE_EATON_USER
    authProtocol = SHA256
    authPassword = &amp;quot;REPLACE_EATON_AUTH_PASSPHRASE&amp;quot;
    privProtocol = AES
    privPassword = &amp;quot;REPLACE_EATON_PRIVACY_PASSPHRASE&amp;quot;
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;The driver uses SNMP port &lt;code&gt;161&lt;/code&gt; by default. If the card uses another port, append it to the address in &lt;code&gt;port&lt;/code&gt; using &lt;code&gt;hostname:port&lt;/code&gt; syntax. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;For a fresh same-host setup, set the local listener in &lt;code&gt;upsd.conf&lt;/code&gt; as shown. If you are creating &lt;code&gt;upsd.users&lt;/code&gt; for this setup, it can start empty. &lt;a href=&quot;https://networkupstools.org/docs/user-manual.chunked/ar01s06.html&quot;&gt;NUT data server configuration&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-text&quot;&gt;LISTEN 127.0.0.1 3493
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;If your package manages NUT services, start the drivers and &lt;code&gt;nut-server&lt;/code&gt; through its service manager. For a manually managed instance, start the drivers first, then the data server. &lt;a href=&quot;https://networkupstools.org/docs/user-manual.chunked/ar01s06.html&quot;&gt;NUT startup instructions&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-sh&quot;&gt;upsdrvctl start
upsd
&lt;/code&gt;&lt;/pre&gt;
&lt;h2&gt;Verify both UPSes in NUT&lt;/h2&gt;
&lt;p&gt;List the UPS names registered with &lt;code&gt;upsd&lt;/code&gt;, then read &lt;code&gt;ups.status&lt;/code&gt; separately for each one. Match the returned status to the UPS&apos;s actual state. For example, &lt;code&gt;OL&lt;/code&gt; indicates line power and &lt;code&gt;OB&lt;/code&gt; indicates battery power. &lt;a href=&quot;https://networkupstools.org/docs/user-manual.chunked/ar01s06.html&quot;&gt;NUT status checks&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/upsc.html&quot;&gt;upsc manual&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-sh&quot;&gt;upsc -l 127.0.0.1
upsc apc-ups@127.0.0.1 ups.status
upsc eaton-ups@127.0.0.1 ups.status
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;If NUT reports stale data or cannot connect to a UPS driver, check that the driver started for that entry. Recheck the corresponding card address, SNMPv3 settings and &lt;code&gt;ups.conf&lt;/code&gt; mapping before proceeding. &lt;a href=&quot;https://networkupstools.org/docs/user-manual.chunked/ar01s06.html&quot;&gt;NUT configuration notes&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.4/docs/man/snmp-ups.html&quot;&gt;NUT driver manual&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Expose both UPSes to Prometheus&lt;/h2&gt;
&lt;p&gt;Download the &lt;code&gt;nut_exporter&lt;/code&gt; binary for your host and save it as &lt;code&gt;nut_exporter&lt;/code&gt;. Make it executable, then start it on the same host with its HTTP listener bound to loopback. &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/releases/expanded_assets/v3.3.0&quot;&gt;Exporter binaries&lt;/a&gt; · &lt;a href=&quot;https://man.freebsd.org/cgi/man.cgi?query=chmod&amp;amp;sektion=1&quot;&gt;chmod manual&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter flags&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-sh&quot;&gt;chmod u+x ./nut_exporter
./nut_exporter --nut.server=127.0.0.1 --nut.serverport=3493 --web.listen-address=127.0.0.1:9199
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;The exporter reads one UPS per request to &lt;code&gt;/ups_metrics&lt;/code&gt;. Give each scrape job the &lt;code&gt;ups&lt;/code&gt; parameter matching its section name in &lt;code&gt;ups.conf&lt;/code&gt;. &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter scrape examples&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Add these jobs under &lt;code&gt;scrape_configs&lt;/code&gt; in &lt;code&gt;prometheus.yml&lt;/code&gt;. If that key already exists, append just the two jobs to its list. Restart Prometheus to apply the changes. &lt;a href=&quot;https://prometheus.io/docs/prometheus/latest/getting_started/&quot;&gt;Prometheus setup guide&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter scrape examples&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-yaml&quot;&gt;scrape_configs:
  - job_name: nut-apc
    metrics_path: /ups_metrics
    params:
      ups: [apc-ups]
    static_configs:
      - targets: [&amp;quot;127.0.0.1:9199&amp;quot;]
  - job_name: nut-eaton
    metrics_path: /ups_metrics
    params:
      ups: [eaton-ups]
    static_configs:
      - targets: [&amp;quot;127.0.0.1:9199&amp;quot;]
&lt;/code&gt;&lt;/pre&gt;
&lt;h2&gt;Confirm that Prometheus has both status series&lt;/h2&gt;
&lt;p&gt;Open &lt;code&gt;/targets&lt;/code&gt; in the Prometheus UI and check that both jobs show &lt;strong&gt;UP&lt;/strong&gt;. Then run the query below in the expression browser and compare each job&apos;s value with its &lt;code&gt;upsc&lt;/code&gt; result. With the exporter&apos;s default status settings, the &lt;code&gt;OL&lt;/code&gt; series is &lt;code&gt;1&lt;/code&gt; when NUT reports that flag and &lt;code&gt;0&lt;/code&gt; when the flag is absent. &lt;a href=&quot;https://prometheus.io/docs/prometheus/latest/getting_started/&quot;&gt;Prometheus verification steps&lt;/a&gt; · &lt;a href=&quot;https://prometheus.io/docs/prometheus/latest/querying/basics/&quot;&gt;PromQL label matchers&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter status handling&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-promql&quot;&gt;network_ups_tools_ups_status{flag=&amp;quot;OL&amp;quot;,job=~&amp;quot;nut-apc|nut-eaton&amp;quot;}
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;If both &lt;code&gt;upsc&lt;/code&gt; checks work but a target is &lt;strong&gt;DOWN&lt;/strong&gt;, check that the exporter is listening at the configured address and that the job passes the correct &lt;code&gt;ups&lt;/code&gt; parameter. If a target is &lt;strong&gt;UP&lt;/strong&gt; and you only see exporter process metrics, check that &lt;code&gt;metrics_path&lt;/code&gt; is &lt;code&gt;/ups_metrics&lt;/code&gt;. The exporter&apos;s &lt;code&gt;/metrics&lt;/code&gt; path serves its process metrics. &lt;a href=&quot;https://prometheus.io/docs/prometheus/latest/getting_started/&quot;&gt;Prometheus target checks&lt;/a&gt; · &lt;a href=&quot;https://github.com/DRuggeri/nut_exporter/blob/v3.3.0/README.md&quot;&gt;Exporter endpoints&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; The setup is based on the NUT 2.8.4 man pages and project guide, the &lt;code&gt;nut_exporter&lt;/code&gt; v3.3.0 README, and the Prometheus documentation. The setup steps were not run.&lt;/p&gt;
</content:encoded><category>snmpv3</category><category>nut</category><category>prometheus</category><category>ups-monitoring</category><author>UPS Card Guide Editorial</author></item><item><title>UPS Management Card vs USB NUT for Rack Shutdown</title><link>https://upscardguide.com/posts/ups-management-card-vs-usb-nut-server-rack/</link><guid isPermaLink="true">https://upscardguide.com/posts/ups-management-card-vs-usb-nut-server-rack/</guid><description>Choose a UPS management card or a dedicated USB NUT server for multi-host rack shutdown. Compare both setups and check the shutdown path.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Choose a UPS management card when you want direct network access to the UPS and NUT&apos;s &lt;code&gt;snmp-ups&lt;/code&gt; driver supports the card. Choose a dedicated USB Network UPS Tools (NUT) server when NUT supports your UPS over USB and every protected host can run a compatible shutdown client. Either NUT design can shut down several hosts sharing one UPS. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/snmp-ups.html&quot;&gt;NUT SNMP driver manual&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Features.html&quot;&gt;NUT multi-host design&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Choose the shutdown path&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Check&lt;/th&gt;
&lt;th&gt;UPS management card with NUT&lt;/th&gt;
&lt;th&gt;Dedicated USB NUT server&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;UPS connection&lt;/td&gt;
&lt;td&gt;A UPS management card can have its own IP address on the LAN. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/snmp-ups.html&quot;&gt;NUT SNMP driver manual&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;A USB cable connects the UPS to the NUT primary. The primary runs the UPS driver, the &lt;code&gt;upsd&lt;/code&gt; data server, and &lt;code&gt;upsmon&lt;/code&gt;. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Features.html&quot;&gt;NUT multi-host design&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Before you buy&lt;/td&gt;
&lt;td&gt;Check the UPS model and card pairing in the NUT hardware list. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/stable-hcl.html&quot;&gt;NUT hardware list&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;Look up the UPS model and USB connection in the hardware list. Use the driver listed for that pairing. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/stable-hcl.html&quot;&gt;NUT hardware list&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT driver setup&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;What must stay up&lt;/td&gt;
&lt;td&gt;The NUT server needs a working network path to the management card. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/snmp-ups.html&quot;&gt;NUT SNMP driver manual&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;The USB-connected primary and network path must stay reachable long enough for secondaries to receive the shutdown signal. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT shutdown sequence&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;In both designs, each protected host other than the primary runs &lt;code&gt;upsmon&lt;/code&gt; as a secondary and needs a working network path to &lt;code&gt;upsd&lt;/code&gt; on the primary. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Features.html&quot;&gt;NUT multi-host design&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If you already have a card and prefer NUT clients, check whether NUT&apos;s &lt;code&gt;snmp-ups&lt;/code&gt; driver supports the card. That setup lets a NUT server communicate with the UPS over the network. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/snmp-ups.html&quot;&gt;NUT SNMP driver manual&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Set up a dedicated USB NUT server&lt;/h2&gt;
&lt;p&gt;This example assumes a single UPS feeding the primary and the other hosts, each with one power supply. It uses a NUT package that honors &lt;code&gt;nut.conf&lt;/code&gt; and a USB UPS listed for &lt;code&gt;usbhid-ups&lt;/code&gt;. If the list shows a different driver, follow its documented &lt;code&gt;ups.conf&lt;/code&gt; settings, including any additional flags it requires. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/stable-hcl.html&quot;&gt;NUT hardware list&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT configuration notes&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/nut.conf.html&quot;&gt;NUT mode settings&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;On the dedicated server, connect the UPS by USB and set &lt;code&gt;MODE=netserver&lt;/code&gt; in &lt;code&gt;nut.conf&lt;/code&gt;. Use these entries in the server&apos;s configuration files. Replace &lt;code&gt;NUT_LAN_IP&lt;/code&gt; with the server&apos;s actual LAN IP and replace the two password placeholders. Keep the credential files readable only by the accounts that need them. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/nut.conf.html&quot;&gt;NUT mode settings&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT configuration notes&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;File on the dedicated server&lt;/th&gt;
&lt;th&gt;Settings&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;code&gt;ups.conf&lt;/code&gt;&lt;/td&gt;
&lt;td&gt;&lt;code&gt;[rackups]&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;driver = usbhid-ups&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;port = auto&lt;/code&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;code&gt;upsd.conf&lt;/code&gt;&lt;/td&gt;
&lt;td&gt;&lt;code&gt;LISTEN 127.0.0.1 3493&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;LISTEN NUT_LAN_IP 3493&lt;/code&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;code&gt;upsd.users&lt;/code&gt;&lt;/td&gt;
&lt;td&gt;&lt;code&gt;[rackprimary]&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;password = PRIMARY_PASSWORD&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;upsmon primary&lt;/code&gt;&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;code&gt;[racksecondary]&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;password = SECONDARY_PASSWORD&lt;/code&gt;&amp;lt;br&amp;gt;&lt;code&gt;upsmon secondary&lt;/code&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;code&gt;upsmon.conf&lt;/code&gt;&lt;/td&gt;
&lt;td&gt;&lt;code&gt;MONITOR rackups@localhost 1 rackprimary PRIMARY_PASSWORD primary&lt;/code&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;On each protected secondary, set &lt;code&gt;MODE=netclient&lt;/code&gt; in &lt;code&gt;nut.conf&lt;/code&gt;. In its &lt;code&gt;upsmon.conf&lt;/code&gt;, use the secondary account and the same LAN IP and password you set on the server. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/nut.conf.html&quot;&gt;NUT mode settings&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT configuration notes&lt;/a&gt;&lt;/p&gt;
&lt;pre&gt;&lt;code class=&quot;language-text&quot;&gt;MONITOR rackups@NUT_LAN_IP 1 racksecondary SECONDARY_PASSWORD secondary
&lt;/code&gt;&lt;/pre&gt;
&lt;p&gt;Use &lt;code&gt;MINSUPPLIES 1&lt;/code&gt; and a &lt;code&gt;SHUTDOWNCMD&lt;/code&gt; appropriate to the OS on both roles. NUT&apos;s Unix example is &lt;code&gt;SHUTDOWNCMD &amp;quot;/sbin/shutdown -h +0&amp;quot;&lt;/code&gt;. On the primary, check that &lt;code&gt;POWERDOWNFLAG&lt;/code&gt; and your OS shutdown hook are configured if you want NUT to turn off UPS output. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT configuration notes&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/upsmon.conf.html&quot;&gt;NUT monitor settings&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;On operating systems with the documented service layout, start the packaged services after applying the configuration. In that layout, &lt;code&gt;nut-server&lt;/code&gt; manages the data server on the primary and &lt;code&gt;nut-monitor&lt;/code&gt; manages &lt;code&gt;upsmon&lt;/code&gt; on each host, including the primary. Query the local and remote status before testing a shutdown. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT configuration notes&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Where&lt;/th&gt;
&lt;th&gt;Read-only check&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Dedicated server&lt;/td&gt;
&lt;td&gt;Run &lt;code&gt;upsc rackups@localhost ups.status&lt;/code&gt;. Look for &lt;code&gt;OL&lt;/code&gt; while the UPS is on line power.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Each secondary&lt;/td&gt;
&lt;td&gt;Run &lt;code&gt;upsc rackups@NUT_LAN_IP ups.status&lt;/code&gt; with the server&apos;s actual IP. Receiving a UPS status value confirms that host can read the UPS state over the LAN.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Dedicated server&lt;/td&gt;
&lt;td&gt;Run &lt;code&gt;upsc -c rackups@localhost&lt;/code&gt; and check that the expected clients are connected. Check the NUT logs for successful monitor logins.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT status and log checks&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/upsc.html&quot;&gt;Read-only upsc commands&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;In the documented low-battery sequence, the primary sets the forced shutdown flag after the UPS reports on-battery and low-battery status. The secondaries start their local shutdowns. The primary waits up to &lt;code&gt;HOSTSYNC&lt;/code&gt; for their monitors to disconnect before proceeding. If a secondary&apos;s &lt;code&gt;FINALDELAY&lt;/code&gt; exceeds the primary&apos;s &lt;code&gt;HOSTSYNC&lt;/code&gt;, the primary stops waiting before that secondary disconnects. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT shutdown sequence&lt;/a&gt; · &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/man/upsmon.conf.html&quot;&gt;NUT monitor settings&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Verify the rack before relying on it&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Keep the signal path powered.&lt;/strong&gt; Put the switch linking the hosts to the card or NUT server on battery-backed power. Do the same for any other network appliance on that path. In the USB design, include the dedicated NUT server in the power plan. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Features.html&quot;&gt;NUT multi-host design&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check host shutdown.&lt;/strong&gt; Observe the host shutdowns when the configured trigger fires. Confirm each OS halts before the battery runs out or the UPS cuts output. With NUT, check the secondary shutdowns and the primary&apos;s wait separately. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT shutdown and test guidance&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check power return.&lt;/strong&gt; If you configured the UPS to turn off its output, verify that output returns as intended. Then confirm that the protected hosts and their monitoring services restart. &lt;a href=&quot;https://networkupstools.org/historic/v2.8.5/docs/user-manual.chunked/Configuration_notes.html&quot;&gt;NUT shutdown and test guidance&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; NUT 2.8.5 documentation was checked on November 26, 2026. The procedures were documented without a hands-on run.&lt;/p&gt;